Over Frequency and Under Frequency

The Under/Over Frequency Relay is sensitive to each underfrequency and over frequency conditions. for example, in associate degree ac power station, it may be wont to defend a generator against beneath speed and/or over speed, as a result of frequency is proportional to hurry.
The mains frequency is that the nominal frequency of the oscillations of electrical energy (AC) in an electrical power system transmitted from an influence station to the end-user.
In massive components of the planet this is often fifty Hz, though within the Americas and components of Asia it’s usually sixty Hz. Current usage by country or region is given within the list of mains power round the world.
Unless such that by the manufacturer to work on each fifty and sixty Hertz, appliances might not operate expeditiously or maybe safely if used on something aside from the meant frequency.
In apply, the precise frequency of the grid varies round the nominal frequency, reducing once the grid is heavily loaded, and dashing up once gently loaded. However, most utilities can change the frequency of the grid over the course of the day to confirm a continuing variety of cycles occur. this is often utilized by some clocks to accurately maintain their time.
With AC, transformers are often wont to step down high transmission voltages to lower client utilization voltage. The electrical device is effectively a voltage conversion device with no moving components and requiring very little maintenance. the employment of AC eliminated the necessity for spinning DC voltage conversion motor-generators that need regular maintenance and observation.
Since, for a given power level, the scale of a electrical device ar roughly reciprocally proportional to frequency, a system with several transformers would be a lot of economical at the next frequency.

Electric power transmission over long lines favors lower frequencies. the consequences of the distributed capacitance and inductance of the road area unit less at low frequency.

Frequency protecting relays on the facility system network sense the decline of frequency and mechanically initiate load shedding or tripping of interconnection lines, to preserve the operation of a minimum of a part of the network. little frequency deviations (i.e.- 0.5 Hertz on a fifty Hertz or sixty Hertz network) can end in automatic load shedding or alternative management actions to revive system frequency.

Smaller power systems, not extensively interconnected with several generators and hundreds, won’t maintain frequency with constant degree of accuracy. wherever system frequency isn’t tightly regulated throughout significant load periods, the system operators could enable system frequency to rise in periods of sunshine load, to take care of a daily average frequency of acceptable accuracy. transportable generators, not connected to a utility system, needn’t tightly regulate their frequency, as a result of typical hundreds ar insensitive to tiny frequency deviations.

 